UNIONS INSTALLATION

Even if the ROTOFLUX unions are rugged and stout, they must be handled with care. For a proper installation we suggest to proceed as follows:

  • Make sure that the fluid system, when new, has been properly cleaned and made free from any machining burr or abrasive particle. In existing fluid system make sure that the filter quality and functionality are in accordance with the normal requirements of hydraulic systems.
  • Clamp in a bench vice the rear of the union and screw up the flexible hose. (sketch 1). Do not use solid pipes.
  • Install the rotary union on to the shaft. (sketch 2)
  • Connect the flexible hose to the supply line. Make sure that the union is not installed taut. (sketch 3)
  • When using metallic flexible hoses in short space with sharp curves, use rigid 45 or 90 elbows to avoid undue stresses. (sketch 4)
  • Check that the union does not rotate eccentric or wobbling.
  • If the fluid is hot or dangerous for any reason, apply a union guard.
  • When required, lubricate periodically the union.
  • Inspect periodically the union to service it and detect any leakage.

WARRANTY

ROTOFLUX warrants that the products are free from any defect in material or workmanship. Unless expressly agreed in writhing, the liability of ROTOFLUX is limited to the replacement or repair of any proved defective union or part, returned to ROTOFLUX, transportation prepaid. The warranty is extended to 12 months from invoice date. There is not warranty, of any kind, extended beyond the limits as written above. ROTOFLUX will not be liable for any damage claimed for the use of defective unions.

IMPORTANT

The use of ROTOFLUX unions with fluid, dangerous because flammeable or corrosive or toxic or explosive, is strictly forbidden. ROTOFLUX reserves the right to modify the catalog without any advise.